Steel Structures By Sk Duggal Pdf | Limit State Design Of

| Step | Calculation | Result | |------|-------------|--------| | 1. Factored load | ( w_d = 1.5 \times 20 = 30 \text kN/m ) ( P_d = 1.5 \times 30 = 45 \text kN ) | — | | 2. Maximum moment | ( M_d = \fracw_d L^28 + \fracP_d L4 = \frac30 \times 6^28 + \frac45 \times 64 = 135 + 67.5 = 202.5 \text kN·m ) | — | | 3. Choose section | IS 2062 I‑250 (Ag= 12 900 mm², Iz= 2.5 × 10⁶ mm⁴) | — | | 4. Plastic moment | ( M_p = 0.66 f_y A_g Z = 0.66 \times 250 \times 12 900 \times 0.9 \approx 1 920 \text kN·m ) | (compact) | | 5. Design strength | ( \phi M_n = 0.9 \times M_p = 1 728 \text kN·m ) | — | | 6. ULS check | ( M_d = 202.5 \text kN·m \le 1 728 \text kN·m ) | | | 7. Deflection (SLS) | ( \Delta = \frac5 w L^4384 E I = \frac5 \times 20 \times 6^4384 \times 200 000 \times 2.5 × 10^6 \approx 7.5 \text mm ) | Limit L/250 = 24 mm → OK |

Subir